Manual – MOVI-PLC® advanced DH.41B Controller
4
Configuration with the MOVITOOLS® MotionStudio PC software
Configuration and Startup
Options for engi-
neering access
You have two options for establishing engineering access to MOVI-PLC
®
advanced
DH.41B via the Ethernet 2 interface (X37).
With point-to-point connection, connect the Ethernet 2 interface (X37) of the
MOVI-PLC
®
advanced DH.41B directly to the Ethernet interface of the engineering
PC. On the engineering PC, choose an interface that is not used to connect the PC
to the intranet/Internet. This prevents the interface from being reconfigured.
Integrate the MOVI-PLC
®
advanced DH.41B control card in a network using the Eth-
ernet 2 interface (X37). Make the necessary address settings by editing the
NetConfig.cfg configuration file in the "System" folder of the SD memory card. The
following options are available for accessing the NetConfig.cfg configuration file:
Remove the SD memory card from the MOVI-PLC
®
advanced DH.41B controller
and plug it into a memory card reader/writer.
First establish a point-to-point connection with the MOVI-PLC
®
advanced DH.41B
control card. Then access the NetConfig.cfg configuration file via an FTP client.
For older network interfaces, it may be necessary to use a cross cable for point-to-
point connection.
Address settings
for a point-to-
point connection
Set the default IP address:
Disconnect the MOVI-PLC
®
advanced DH.41B control card from the voltage
supply.
Change DIP switch S1 to the top position.
Apply voltage to the MOVI-PLC
®
advanced DH.41B control card. The IP address
192.168.10.5 and the net mask 255.255.255.0 is automatically assigned to the
Ethernet 2 interface of the MOVI-PLC
®
advanced DH.41B control card.
Set a different address:
You can set other addresses by editing the <Ethernet2...> section manually in the
NetConfig.cfg configuration file in the "System" folder of the SD memory card.
Example:
<!-- Ethernet2 is engineering interface -->
<Ethernet2>
<IPAddress>192.168.10.5</IPAddress>
<Netmask>255.255.255.0>/Netmask>
<Gateway>192.168.10.1</Gateway>
<Nameserver>0.0.0.0</Nameserver>
<Hostname>MOVI-PLC_Eth2>/Hostname>
</Ethernet2>
Change DIP switch S1 to the bottom position. Doing so makes sure that the address-
es will take effect when the MOVI-PLC
®
advanced DH.41B is restarted.