Master GREEN 115 Bedienerhandbuch Seite 3

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 10
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 2
DESCRIPTION
Warning: Only the burners which are chosen and sup-
plied by the manufacturer can be used. If another type
of burner is used the heater no longer complies with CE
regulations.
GREEN space heaters have been designed for use in small
to medium-sized rooms and buildings where a xed or mobile
heating system is required.
Heat is produced by combustion and the heat from the smoke
is transmitted to the fresh air through the metal walls of the
combustion chamber and the heat exchanger. The combustion
chamber is of the type where smoke circulates twice.
The air and smoke pass through separated ducts, both of which
are welded and sealed. When, after combustion, the waste ga-
ses have cooled, they are expelled through a duct which must
be connected to a chimney or chimney ue. The chimney or
chimney ue must be big enough to guarantee that the smoke
is expelled ef ciently.
The air which is used in combustion is aspirated directly from the
room or building which is being heated. It is therefore of utmost
importance that the room or building be properly ventilated so
that enough fresh air is circulating at all times.
GREEN heaters can operate with burners that are fuelled by
heating oil, methane (G20) or L.P.G. (butane G3O and propane
G31) of the ON-OFF type.
There are three safety devices which are activated in case of
serious malfunction. The Burner Control Device, which is moun-
ted on the burner and has a restart button, automatically stops
the burner if the ame goes out. The Overhrat Thermostat, L2,
of the manuel restart type, is activated if the temperature of the
combustion chamber rises above the set maximum limit; the
warning light (9) lights up and the heater stops working. The
Thermal Relay, RM, is activated if the fan motor starts to use
more electrical current than the maximum permitted limit; the
warning light (10) lights up and the heater stops working.
If any of these safety devices are activated you should check
carefully what the problem actually is before pressing the restart
button and starting the heater off again (“OBSERVED FAULTS,
CAUSES AND REMEDIES”). Overheat safety thermostat, L1,
shuts down the heater if air ow is not suf cient to cool off com-
bustion chamber: the heater will restart automatically as soon as
the heater has cooled down enough (the lamp(9) lights up and
then it cuts down).
GENERAL ADVICES
The space heater must be installed, set up and used in accor-
dancewith existing laws.
Here are a few general guidelines which should be followed:
• Follow the instructions in this booklet very carefully;
Don’t install the heater in places where there may be a risk of
re or explosion;
In ammable material should be kept at a safe distance from
the heater (Minimum 3 meters);
• All re prevention regulations must be adhered to;
The room or building which is being heated must be suf ciently
ventilated so that the heater has enough air to function pro-
perly;
The heater must be near a chimney or chimney ue and a sui-
table electric switchboard;
• Don’t let animals or children near the heater;
After use make sure the disconnecting switch is off.
When using any type of space heater it is obligatory:
not to exceed the maximum level of heat output of the furnace
(“TECHNICAL SPECIFICATION TABLE”);
to make sure that there is adequate air circulation and air sup-
plyto the heater and that nothing is obstructing the aspiration
and expulsion of air; movement of air may be obstructed in
various ways including placing covers or other objects on the
heater or positioning the heater too near a wall or other large
object. If the air ow is not adequate, the combustion chamber
will over heat and the overheat safety thermostat L1 will turn
the burner off and on continnously (“OBSERVED FAULTS,
CAUSES AND REMEDIES”).
INSTALLATION
Warning: The following operations must be carried out by
quali ed personnel only.
ELECTRICAL CONNECTIONS AND SETTINGS
Warning: The mains supply to the heater must be earthed
and have a magneto-thermal switch with differential.
The power cord must be connected to a switch board
which has a disconnecting switch.
Every space heater is supplied along with the safety and control
devices which are indispensable to the correct functioning of the
unit.The electric switchboard, burner, the fan thermostat, over
heat safety thermostat and the overheat thermostat with manual
restart have already been connected.
The following operations must now be carried out:
Plug in the power cord having read the adhesive label whi-
ch details electricity supply characteristics (Table 1). Table 2
shows the adhesive label on units which have three-phase
supply;
Model
M - M/C
Model
T - T/C
Number of phases 1 3
Tension 230 230/400
Frequency 50 50
The burner must be connected to the fuel supply (“Burner In-
struction Manual”);
Connect the burner to the electricity supply with the burner
plug;
Connect accessories such as the room thermostat or clock to
the unit’s electric switchboard: electric wire must be connected
by means of the cable fastener (8) to the terminals (6) and (7).
Having completed all these operations check carefully that all
electrical connections correspond to the wiring diagram. When
the heateris rst turned on you must check that the fan does not
use more current than the maximum permitted limit. Finally, to
HOT AIR GENERATOR
7
GB
Tab. 1
[V]
[Hz]
230V - 3~ - 50Hz
400V - 3~ - 50Hz
Tab. 2
Seitenansicht 2
1 2 3 4 5 6 7 8 9 10

Kommentare zu diesen Handbüchern

Keine Kommentare